phone 877.726.0886 Contact Us
res menu

Phantom XL Dilators/Neuro Monitoring

Phantom XL3 Dilator Holder, Ring Handled

Facilitates the deployment of insulated Phantom XL Dilators during intraoperative fluoroscopic imaging to minimize exposure to radiation.

Read more

Facilitates the deployment of insulated Phantom XL Dilators during intraoperative fluoroscopic imaging to minimize exposure to radiation.

Phantom XL Pedicle Screw Probe, Single Use, 10/box, Sterile

Provides an excellent means of stimulating pedicle screws. The shaft is insulated to help prevent current shunting and the exposed Ø2.3mm ball tip provides a perfect contact area for stimulation. A 30-degree bend may be placed in the shaft of the probe for use under a microscope. Lead length 200cm / 78in.

Read more

Provides an excellent means of stimulating pedicle screws. The shaft is insulated to help prevent current shunting and the exposed Ø2.3mm ball tip provides a perfect contact area for stimulation. A 30-degree bend may be placed in the shaft of the probe for use under a microscope. Lead length 200cm / 78in.

Phantom XL Dilator Clip, Single Use, 1/each, Sterile

Clip-on style lead wire, 1.5mm touch-proof connector with a multi-stage wire form that auto-adjusts to any diameter up to 3/4". Compatible with Phantom ML Insulated Dilators.

Read more

Clip-on style lead wire, 1.5mm touch-proof connector with a multi-stage wire form that auto-adjusts to any diameter up to 3/4". Compatible with Phantom ML Insulated Dilators.

Phantom XL Insulated Dilator, 8, 13, 18 MM, 3/set, Single Use, Sterile

Facilitates the localization of targeted anatomy using neuromonitoring and dilation of tissue and muscle adjacent to the lumbar spine. Delicately designed outer coating and ultra-sensitive triangular stimulating electrodes ensure consistent and safe navigation through the psoas and neural plexus.

Read more

Facilitates the localization of targeted anatomy using neuromonitoring and dilation of tissue and muscle adjacent to the lumbar spine. Delicately designed outer coating and ultra-sensitive triangular stimulating electrodes ensure consistent and safe navigation through the psoas and neural plexus.

Phantom K-wires

Stainless steel wires used in multiple roles during internal fixation as a temporary measure before more definitive fixation in MIS lumbar surgery.

Read more

Stainless steel wires used in multiple roles during internal fixation as a temporary measure before more definitive fixation in MIS lumbar surgery.

Book a Demo Today